YASKAWA G7 Series Technical Manual page 381

Table of Contents

Advertisement

Switch
o1-03 F3-01
S1
12 bits
3-digit BCD with sign, 1%
0
16 bits
4-digit BCD with sign, 1%
12 bits
3-digit BCD with sign, 0.1%
1
16 bits
4-digit BCD with sign, 0.1%
12 bits
3-digit BCD with sign, 0.01%
2
16 bits
4-digit BCD with sign, 0.01%
12 bits
3-digit BCD with sign, 1Hz
3
0 or 1
16 bits
4-digit BCD with sign, 1Hz
12 bits
3-digit BCD with sign, 0.1Hz
4
16 bits
4-digit BCD with sign, 0.1Hz
12 bits
3-digit BCD with sign, 0.01Hz
5
16 bits
4-digit BCD with sign, 0.01Hz
6
16 bits
5-digit BCD without sign, 0.01Hz
12 bits
12-bit binary with sign, 100%/4095
7
16 bits
16-bit binary with sign, 100%/30000
12 bits
3-digit BCD with sign, 1 rpm
2 to 39
-
16 bits
4-digit BCD with sign, 1 rpm
3-digit BCD with sign, 100%/(1- to 4-
-
12 bits
digit setting of o1-03)
40 to
39999
4-digit BCD with sign, 100%/(1- to 4-
-
16 bits
digit setting of o1-03)
10000
x = 1
-
16 bits
4-digit BCD with sign, 100%/10000
to 3
DI-08 Reference Ranges
When using the DI-08, the following ranges can be set depending on the settings of the parameters.
F3-01
Reference Input Mode
0
2-digit BCD with sign, 1%
1
2-digit BCD with sign, 0.1%
2
2-digit BCD with sign, 0.01%
3
2-digit BCD with sign, 1Hz
4
2-digit BCD with sign, 0.1Hz
5
2-digit BCD with sign, 0.01Hz
6
12-bit binary with sign, 100%/
7
4095
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Reference Input Mode
Reference Setting Range
-110 to 110%
-15.9 to 15.9%
-1.59 to 1.59%
-159 to 159Hz
-15.9 to 15.9Hz
-1.59 to 1.59Hz
-
-255 to 255
U1-01 Monitor Unit
Reference Setting
Range
o1-03 = 0
-110 to 110%
-110 to 110%
-110.0 to 110.0%
-110.0 to 110.0%
-15.99 to 15.99%
-110.0 to 110.0%
-400 to 400Hz
-400 to 400Hz
0.01Hz
-159.9 to 159.9Hz
-400.0 to 400.0Hz
-15.99 to 15.99Hz
-159.99 to 159.99Hz
000.00 to 399.98Hz
-4095 to 4095
-33000 to 33000
-1599 to 1599 rpm
-15999 to 15999 rpm
-4095 to 4095
5th digit of o1-03 set-
ting:
-10999 to 10999
X = 0, unit: 1
(when o1-03 = 9999)
X = 1, unit: 0.1
X = 2, unit: 0.01
X = 3, unit: 0.001
-11000 to 11000
U1-01 Monitor Unit
o1-03 = 0
0.01Hz
Options
o1-03 = 1
0.01%
1 rpm
1 rpm
o1-03 = 1
0.01%
163
6-

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents