Setting
Value
C
Multi-function analog input selection (ON: Enable)
D
No V/f control with PG (ON: Speed feedback control disabled,) (normal V/f control)
E
Speed control integral reset (ON: Integral control disabled)
F
Not used (Set when a terminal is not used)
10
Up command (Always set with the down command)
11
Down command (Always set with the up command)
12
FJOG command (ON: Forward run at jog frequency d1-17)
13
RJOG command (ON: Reverse run at jog frequency d1-17)
14
Fault reset (Reset when turned ON)
Emergency stop. (Normally open condition: Deceleration to stop in deceleration
15
time set in C1-09 when ON.)
16
Motor switch command (Motor 2 selection)
Emergency stop (Normally closed condition: Deceleration to stop in deceleration
17
time set in C1-09 when OFF)
Timer function input (Functions are set in b4-01 and b4-02 and the timer function
18
outputs are set in H1-
19
PID control disable (ON: PID control disabled)
1A
Accel/Decel time 2
Parameters write enable (ON: All parameters can be written-in. OFF: All
1B
parameters other than frequency monitor are write protected.)
1C
Trim control increase (ON: d4-02 frequency is added to analog frequency reference.)
Trim control decrease (ON: d4-02 frequency is subtracted from analog frequency
1D
reference.)
1E
Analog frequency reference sample/hold
20 to
External fault (Desired settings possible)
2F
Input mode: NO contact/NC contact, Detection mode: Normal/during operation
PID control integral reset (reset when reset command is input or when stopped
30
during PID control)
31
PID control integral hold (ON: Hold)
32
Multi-step speed reference 4
34
PID soft starter
35
PID input characteristics switch
60
DC injection braking command (ON: Performs DC injection braking)
61
External search command 1 (ON: Speed search from maximum output frequency)
62
External search command 2 (ON: Speed search from set frequency)
63
Field weakening command (ON: Field weakening control set for d6-01 and d6-02)
64
External speed search command 3
65
KEB (deceleration at momentary power loss) command (NO contact)
66
KEB (deceleration at momentary power loss) command (NO contact)
Communications test mode ("Pass" is displayed when the communications test is
67
passed.)
68
High-slip braking (HSB)
Jog 2
69
Closed = Drive runs at frequency reference entered into parameter d1-17.
Direction is determined by FWD/REV input. Three-wire control only
Drive Enable
6A
Closed = Drive will accept run command.
Open = Drive will not run. If running , drive will stop per b1-03.
-52
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Function
and H2-
.)
Control Methods
Open
Open
V/f
Loop
Flux
Loop
V/f
with
Vector
Vector
Vector
PG
1
2
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
Yes
No
Yes
Yes
-
-
-
-
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes