Setting Method Using Combination Of W-Series And Ns115 - Omron SYSMAC CS1G Operation Manual

Motion control unit
Table of Contents

Advertisement

Servo Parameter
No.
Name
900C
Multi-turn limit
900D
Position loop
gain address
900E
Position loop
gain index
4-8-4

Setting Method Using Combination of W-Series and NS115

User constant
No.
Pn004.1
Electronic gear conversion of the
feedback count in position control
Pn004.2
Control mode switch
Pn004.3
Access cycle S-shape filter
Pn200.2
Clear operation
Pn207.1
Position control option
Pn50A.0
Input allocation
Pn50A.1
/SVON
Pn50B.1
/ALMRST
Pn50C
/SPD-D, -A, -B, /C-SEL
186
Configuration and explanation
15
00
Multi-turn
• Sets the No. of multi-turns of an absolute
encoder.
When using an axis as an infinite length
axis, make sure to set the same value set
in Pn205 of the servo driver.
• Setting range 0 to FFFF Hex (0 to 65535)
15
00
Position loop gain address
• This is the address of the position loop
gain.
Note Selecting the motor model automati-
cally sets this parameter.
Note Entering numerical value cannot
change this parameter.
15
00
Position loop gain index
• Sets the unit system for the position loop
gain.
Note Selecting the motor model automati-
cally sets this parameter.
Note Entering numerical value cannot
change this parameter.
This section explains the servo driver's parameter setting method with combi-
nation of W-series servo driver and NS115.
The following user constants are expressed as restricted constant, deter-
mined constant, expansion constant, and disabled constant.
Determined constant: To be reset to the settings in the following table if the
value is outside of the setting value when the power is turned ON.
Approximately three seconds will be added during the re-setting.
Expansion constant: This is the parameter to expand a function when install-
ing the NS115.
Disabled constant: Neither alarm nor warning occurs even when changed.
Name
Type
Data
Data
Data
Content
No conversion
Execute
Disable
Clears only with CLR com-
mand.
Speed feed forward on V-REF 1
Input signal custom setting
Disable
Disable
Disable
Section 4-8
Initial
Unit
value
FFFF
---
(65535)
0000 (0)
---
0000 (0)
---
Setting
Remark
0
Determined constant
1
Determined constant
0
Determined constant
1
Determined constant
Determined constant
1
Determined constant
8
Determined constant
8
Determined constant
8888
Determined constant
Immediate
updating
No
No
No

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cs1w-mch71Sysmac cs seriesSysmac cs1h

Table of Contents