Omron SYSMAC CS1G Operation Manual page 99

Motion control unit
Table of Contents

Advertisement

System Parameters
No.
Address in MC
Unit
P2AA10
55C9h +
(AA * 14h)
Data configuration
31
S-curve filter enabled
Note
No.
Address in MC
Unit
P2AA11
55CAh +
(AA * 14h)
Data configuration
31
S-curve time constant
Note
No.
Address in MC
Unit
P2AA12
55CBh +
(AA * 14h)
Data configuration
31
S-curve time constant
Note
Axis-Position Parameters
Note
No.
Address in MC
Unit
P3AA01
5840h +
(AA * 14h)
Data configuration
31
Travel distance
76
Name
Manual feed S-curve filter enabled Data
Setting range
00000000 to 00000001 Hex
00
(0 to 1)
Explanation
Selects the S-curve filter enable/disable at manual feed rate.
0: Disabled
1: Enabled
For details of Accel/decel patterns, see 6-1-5 Axis Movement Operation
(page 228).
Name
Rapid feed S-curve time constant
Setting range
00000000 to 00007530 Hex
00
(0 to 30000)
Explanation
Sets the S-curve filter time constant at rapid feed rate.
For details of Accel/decel patterns, see 6-1-5 Axis Movement Operation
(page 228).
Name
Manual feed S-curve time constant Data
Setting range
00000000 to 00007530 Hex
00
(0 to 30000)
Explanation
Sets the S-curve filter time constant at manual feed rate.
For details of Accel/decel patterns, see 6-1-5 Axis Movement Operation
(page 228).
Abbreviation in the No. column:
Abbreviation in the address column: AA=0-31 (axis number − 1)
Name
STEP operation travel distance
Setting range
00000000 to 7FFFFFFF Hex
00
(0 to 2147483647)
Type
Unit
---
Type
Unit
Data
ms
Type
Unit
ms
AA=1-32 (axis number)
Type
Unit
Data
Command unit
Section 4-2
Immediate
updating
Yes
Initial value
00000000 (0)
Immediate
updating
Yes
Initial value
00000064 (100)
Immediate
updating
Yes
Initial value
00000064 (100)
Immediate
updating
Yes
Initial value
000003E8 (1000)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cs1w-mch71Sysmac cs seriesSysmac cs1h