IORD Instruction to Transfer Data
Procedure
1,2,3...
214
• Setting values for specifying the servo parameter axis are to be [Axis No.
- 1] as shown below:
Axis No.
Setting value for axis specification
1
0h
2
1h
3
2h
:
:
30
1Dh
31
1Eh
32
1Fh
• IORD/IOWR control addresses (addresses in the MC Unit) corresponding
to the parameter Nos. (Pn000 to Pn8FF) of the servo driver are as shown
below:
Parameter No.
Pn000
7000h
Pn001
7001h
Pn002
7002h
:
:
Pn8FD
78FDh
Pn8FE
78FEh
78FFh
Pn8FF
1. Set the data in the data area of the transfer source.
2. Specify the servo parameter axis.
3. Read the parameter setting values for the number needed.
Address in MC Unit
Section 5-3