626/653
Appendix
Code
H9.10 Relay output setting value
H9.97 Relay card output channel diagnosis
Setting range of H9.00...H9.03:
0: Converter ready
1: Converter running
2: Converter DC-braking
3: Converter running at zero speed
4: Speed arrival
5: Frequency level detection signal (FDT1)
6: Frequency level detection signal (FDT2)
7: Simple PLC stage complete
8: Simple PLC cycle complete
10: Converter undervoltage
11: Converter overload pre-warning
12: Motor overload pre-warning
13: Converter stop by external error
14: Converter error
15: Converter OK
Bosch Rexroth AG R912005854_Edition 09
Name
Rexroth Frequency Converter EFC x610
Setting range
Relay1 is defined by bit0,
when bit0 is '0', R1b_R1a
is opened; when bit0 is
'1', R1b_R1a is closed
Relay2 is defined by bit1,
when bit1 is '0', R2b_R2a
is opened; when bit1 is
'1', R2b_R2a is closed
Relay3 is defined by bit2,
when bit2 is '0', R3b_R3a
is opened; when bit2 is
'1', R3b_R3a is closed
Relay4 is defined by bit3,
when bit3 is '0', R4b_R4a
is opened; when bit3 is
'1', R4b_R4a is closed
0: Inactive
1: Relay1 diagnosis
2: Relay2 diagnosis
3: Relay3 diagnosis
4: Relay4 diagnosis
5: All output diagnosis
Series
Default
Min.
Attri.
0
Run
0
Stop