84/653
Electromagnetic Compatibility (EMC)
Minimum immunity requirements for PDSs intended for use in the first environ-
ment
Port
Phenomenon
ESD
Radio-frequency electromag-
netic field, amplitude modula-
ted
Fast transient-burst
Surge 1.2/50 μs, 8/20 μs
Conducted radio-frequency
common mode
Fast transient-burst
Fast transient-burst
Conducted radio-frequency
common mode
CD: Contact discharge
AD: Air discharge
AM: Amplitude modulation
Tab. 9-2: Minimum immunity requirements for PDSs intended for use in the first environ-
ment
Category C1 is only for conducted emission, radiated emission
needs checking with metallic cabinet. For installation, see
9.3 "EMC Measures for Design and Installation" on page
Bosch Rexroth AG R912005854_Edition 09
Rexroth Frequency Converter EFC x610
Basic standard
for test
method
4 kV CD or 8 kV AD
IEC 61000-4-2
if CD impossible
80 ~ 1000 MHz 3 V/m
1.4 ~ 2.0 GHz 3 V/m
IEC 61000-4-3
2.0 ~ 2.7 GHz 1 V/m
80 % AM (1 kHz)
IEC 61000-4-4 1 kV/5 kHz
IEC 61000-4-5 1 kV
a
, 2 kV
0.15 ~ 80 MHz 3 V
IEC 61000-4-6
80 % AM (1 kHz)
1 kV/5 kHz
IEC 61000-4-4
Capacitive clamp
0.5 kV/5 kHz
IEC 61000-4-4
Capacitive clamp
0.15 ~ 80 MHz 3 V
IEC 61000-4-6
80 % AM (1 kHz)
a
: Coupling line to line
b
: Coupling line to earth
Performance
Level
(acceptance
criterion)
b
chapter
92.
Series
B
A
B
B
A
B
B
A