– E2.26 = 13: Setting torque
Represents range of setting torque selected using C3.42 and C3.43.
– E2.26 = 14: Output torque
Represents range of output torque selected using C3.42 and C3.43.
Step 3: Set AO1 filter time and output curve
AO1
AO1 output
OUT
Ref.
Reference
Fig. 12-89: AO1 output curve
Analog output status is monitored by parameter d0.35 'AO1 output'.