Accessories
Fig. 15-54: Shielded cable connection with accessories for K housing (FEAM03.2-005-NN-
NNNN)
Connection steps
Step 1: Place holes ① of the connector on the two screw holes outside of sym-
bols
and tighten two screws.
Step 2: Insert the shielded cables through component ② of the connector with
the shielding layer reliable contact with the metal.
When double cables are used, put double cables in one clamp.
Step 3: Tighten sixteen screws of the accessories.
Step 4 (Optional): Fix the STO cable to the side of shielding connector.
Step 5 (Optional): Tighten two screws of the accessories.