144/653
Functions and Parameters
Fig. 12-17: Stall overcurrent at constant speed
[Output current] > [C0.27]
The output frequency decreases till the output current is lower than [C0.27]
with defined deceleration time.
[Output current] < [C0.27]
The output frequency increases to the setting frequency with defined acceler-
ation time.
This function can have influence on the speed accuracy during con-
stant running and on the acceleration performance.
Bosch Rexroth AG R912005854_Edition 09
Rexroth Frequency Converter EFC x610
Series