12.9.6 Motor Temperature Sensor Channel
This function defines the motor temperature sensor channel selection when pro-
tect the motor from overheat.
Code
Name
Motor temperature sen-
E1.60
sor channel
Setting range of E1.60:
0: Inactive
●
Inactivate the function of temperature monitoring with temperature sensor:
1: AI1 analog input
●
Motor temperature sensor channel is AI1.
2: AI2 analog input
●
Motor temperature sensor channel is AI2.
3: EAI1 analog input
●
Motor temperature sensor channel is EAI1.
4: EAI2 analog input
●
Motor temperature sensor channel is EAI2.
5: TSI input (only for IO plus card)
●
Motor temperature sensor channel is TSI when IO plus card was used.
AI1 / AI2 / EAI1 / EAI2 will be automatically set as voltage input
mode when [E1.60] = 1...4.
Setting range
0: Inactive
1: AI1 analog input
2: AI2 analog input
3: EAI1 analog input
4: EAI2 analog input
5: TSI input (only for
IO plus card)
R912005854_Edition 09 Bosch Rexroth AG
Functions and Parameters
Default
Unit
Step
0
-
245/653
Attri.
-
Stop