12.22.4 IO & IO Plus Card Digital Output Configuration
This function defines the IO and IO plus extension card open collector output
for system state monitoring.
Code
Name
H8.20 EDO1 output selection
H8.22 EDO2 output selection
Extended digital output
H8.23
value from extension card
fieldbus communication
Setting range of H8.20, H8.22:
0: Converter ready
After power on, when no error happens, no run command, output active indi-
cates that the converter is ready for running.
1: Converter running
The output is active when the frequency converter is running and has fre-
quency output (including 0.00 Hz).
2: Converter DC-braking
The output is active when the converter is in the DC braking process at start-
ing or stopping process. See
page 210
and
chapter 12.8.9 "Stop Mode Configuration" on page
3: Converter running at zero speed
The output is active when the frequency converter is running at zero speed.
There is no output for this selection during dead zone time of rota-
tion direction change.
4: Speed arrival
This function is used to detect the difference between the output frequency
and the set frequency. The indicative signals are outputted when the differ-
ence between the output frequency and the set frequency is within the range
set in [E2.70], see
258.
5: Frequency level detection signal (FDT1)
6: Frequency level detection signal (FDT2)
See
chapter 12.10.5 "Frequency Detection Function" on page
7: Simple PLC stage complete
8: Simple PLC cycle complete
See
chapter 12.11 "E3: Multi-Speed and Simple PLC" on page
Bosch Rexroth AG R912005854_Edition 09
Setting range
0...25
Bit0: EDO1 (IO / IO plus
card)
Bit1: EDO2 (IO plus card)
Bit8: Erelay (IO card)
chapter 12.8.7 "Start Mode Configuration" on
chapter 12.10.5 "Frequency Detection Function" on page
Rexroth Frequency Converter EFC x610
Default
1
1
0
Series
Unit
Step
Attri.
Stop
Stop
Stop
216.
258.
262.