Functions and Parameters
Communication frequency setting register (0x7F01)
The address of frequency setting register for communication control is 0x7F01.
This register is for read and write. When 'First frequency setting source' [E0.00]
= '20: Communication', the frequency converter can be set with writing data to
this address.
Torque setting register (0x7F02)
The address of torque setting register is 0x7F02. This register is for read and
write. When 'Torque reference channel' [C3.41] = '6: Communication', the torque
reference channel can be set with writing data to this address.
Torque FWD limitation register (0x7F03)
The address of torque FWD limitation register is 0x7F03. This register is for read
and write. When 'Torque limitation reference selection at speed control mode'
[C3.47] = '4: Communication', the torque limitation reference can be set with
writing data to this address.
Torque REV limitation register (0x7F04)
The address of torque REV limitation register is 0x7F04. This register is for read
and write. When 'Torque limitation reference selection at speed control mode'
[C3.47] = '4: Communication', the torque limitation reference can be set with
writing data to this address.
Speed limitation register (0x7F05)
The address of speed limitation register is 0x7F05. This register is for read and
write. When 'Speed limitation reference selection at torque control mode'
[C3.48] = '4: Communication', the speed limitation reference can be set with
writing data to this address.