128/653
Functions and Parameters

12.2.2 Normal Duty / Heavy Duty Setting

This function is used to set duty rating according to the load type of application.
Code
Name
C0.01 Normal / Heavy duty setting
For some light load application, it is possible to use a lower power size frequen-
cy converter to drive a higher power size motor with normal duty setting.
After parameter initialization the device and motor settings will be set to HD
mode
Switching from HD to ND will cause motor parameters reset to default value
of normal duty, and vice versa.
Switching from HD to ND will cause carrier frequency reset to default value of
normal duty, and vice versa.
This function is only available for 5.5kW and above devices.
Overload capability and output current in ND and HD modes are shown as be-
low:
Overload
(%)
110
120
130
140
150
160
170
180
190
200
Bosch Rexroth AG R912005854_Edition 09
Rexroth Frequency Converter EFC x610
Setting range
0: Normal duty (ND)
1: Heavy duty (HD)
HD
-
400
149
88
60
42
13
3.2
1.5
1.0
Default
Unit
Step
1
ND
200
60
22
13
10
-
-
-
-
-
Series
Attri.
Stop

Advertisement