Bosch rexroth EFC 610 Series Operating Instructions Manual page 630

Frequency converter
Hide thumbs Also See for rexroth EFC 610 Series:
Table of Contents

Advertisement

596/653
Appendix
Code
E0.73 Skip frequency range
Skip window acceleration
E0.74
factor
: percentage of frequency converter rated current.
Setting range of E0.00, E0.02:
0: Panel potentiometer
1: Panel button setting
2: AI1 analog input
3: AI2 analog input
4: EAI1 analog input
5: EAI2 analog input
10: X5 pulse input
11: Digital input Up / Down command
20: Communication
21: Multi-speed settings
Setting range of E0.01, E0.03:
0: Panel
1: Multi-function digital input
2: Communication
Setting range of E0.04:
0: No combination
1: First frequency setting + second frequency setting
2: First frequency setting - second frequency setting
3: First frequency setting x second frequency setting
4: Bigger one of 2 sources
5: Smaller one of 2 sources
6: Valid which channel is non-zero
Setting range of E0.06:
0: Not saved when powered off or stopped
1: Not saved when powered off; saved when stopped
2: Saved when powered off; not saved when stopped
3: Saved when powered off or stopped
4: Not saved when powered off; memorized when stopped
Bosch Rexroth AG R912005854_Edition 09
Name
0.00...30.00 Hz
1...100
Rexroth Frequency Converter EFC x610
Setting range
Series
Default
Min.
Attri.
0.00
0.01
Stop
1
1
Stop