284/653
Functions and Parameters
12.13 E5: Extended Application Functions
12.13.1 High Resolution Current Display
E5.01 is used to set the time constant of dynamic output current in applications
where a high resolution value with two decimals are required for monitoring or
control.The high resolution output current can be monitored via d0.98.
Code
Name
High resolution output current
E5.01
filter time
12.13.2 Speed Display Scaling
This function is used to display an engineering value which is convenient for the
application engineering with scaling the output value.
Code
Name
User-defined speed scaling fac-
E5.02
tor
Follow the equations below:
User-defined setting speed:
●
[d0.04] = [d0.02] x [E5.02]
User-defined output speed:
●
[d0.05] = [d0.00] x [E5.02]
Bosch Rexroth AG R912005854_Edition 09
Rexroth Frequency Converter EFC x610
Setting range
Default
5...500 ms
40
Setting range
Default
0.01...100.00
1.00
Series
Unit
Step
Attri.
ms
1
Run
Unit
Step
Attri.
-
0.01
Run