Rexroth Frequency Converter EFC x610
Series
Non-Volatile Storage
The following objects are implemented:
1. 0x1010: Store Parameter Field
2. 0x1011: Restore Default Parameter
Saving the contents of object (parameter) data value happens
●
whenever it is written and the already saved data value is differ-
ent. Saving of objects in EEPROM is handled.
Only communication and device profile objects of CANopen op-
●
tion card parameters are restored to default values upon com-
mand to object 0x1011.
Manufacturer specific parameter/objects are not restored to de-
●
fault values upon command to object 0x1011.
The following CANopen option card parameters are not restored
●
to default values upon command to object 0x1011:
– [H2.00] – Node Address
– [H2.01] – CAN Baudrate
– [H2.02] – CANopen Device Profile Selection
– [H2.98] – CANopen Termination Resistor Switch
Functions and Parameters
R912005854_Edition 09 Bosch Rexroth AG
369/653