Rexroth Frequency Converter EFC x610
Series
Fig. 12-152: Example code_2
12.20.7 EtherCAT
Protocol Configuration
For EtherCAT, the IP address configuration is done on master's side. From Ether-
CAT state PreOp, Ethernet over EtherCAT (EoE) is started and IndraWorks Ds
can be used.
System Configuration
Configuration File
An EtherCAT master requires both, an EtherCAT Slave Information (ESI) and an
Electronic Data Sheet (EDS) file in order to fully support an EtherCAT slave run-
ning CoE (CAN over EtherCAT). The former provides a slave device description
for EtherCAT PLCs and some information for configuring the EtherCAT communi-
cation. The latter describes accessible CAN objects of the device.
Users can download the target files through the following steps:
1. Click on http://www.boschrexroth.com/dcc.
2. Choose "Frequency converter -> EFC 3610 (or EFC 5610)" from the naviga-
tion bar on left-hand side of the operation interface.
3. Choose "Download area" tab from right-hand side of the interface.
4. Click
on
xx.ZIP" to download the ZIP file.
5. Extract the ZIP file and get the target files.
"DEVICE_DESCRIPTIONS_MULTI-ETHERNET_EFCX610_xxxx-xx-
Functions and Parameters
R912005854_Edition 09 Bosch Rexroth AG
429/653