Bosch rexroth EFC 610 Series Operating Instructions Manual page 364

Frequency converter
Hide thumbs Also See for rexroth EFC 610 Series:
Table of Contents

Advertisement

330/653
Functions and Parameters
Speed limitation at torque control mode from fieldbus
H0.16 is used to set Speed limitation at torque control mode when [C3.48] = '4:
Communication' and when communication protocol [E8.00] = '1: Extension
card', setting value 0.00...655.35 representing 0.00...655.35Hz.
Code
Name
Speed limitation at tor-
H0.16
que control mode from
fieldbus
Speed limitation refer-
C3.48
ence selection at torque
control mode
E8.00 Communication protocol 1: Extension card
Fieldbus voltage command
H0.50 is used to set V/f separation output voltage when [C2.08] = '20: Commu-
nication' and when communication protocol [E8.00] = '1: Extension card', setting
value 0.00...100.00 representing 0.00...100.00% rated voltage.
Code
Name
Fieldbus voltage com-
H0.50
mand
V/f separation output
C2.08
voltage source selection
E8.00 Communication protocol 1: Extension card
Bosch Rexroth AG R912005854_Edition 09
Rexroth Frequency Converter EFC x610
Setting range
0.00...655.35
4: Communication (Speed
limitation register: Modbus
0x7F05/Fieldbus exten-
sion card H0.16)
Setting range
0.00...100.00 %
20: Communication (Mod-
bus 0x7F0B/ Fieldbus ex-
tension card H0.50)
Default
Unit
Step
0.00
-
0.01
0
-
-
0
-
-
Default
Unit
Step
0.00
%
0.01
22
-
-
0
-
-
Series
Attri.
Run
Stop
Stop
Attri.
Run
Stop
Stop

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth efc 3610Rexroth efc 5610

Table of Contents