Xerox WorkCentre C2424DX Service Manual page 210

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

Voltages
This test determines averaged readings for key system voltages.
R#
Definition
Main Board Voltages
5 Volts (volts)
0
1.8 Volts (volts)
1
2.5 Volts (volts)
2
3.3 Volts (volts)
3
unregulated12 Volts
4
(volts)
2.5 Volts (volts)
5
unregulated
6
Negative 12 Volts
(volts)
Control Board Voltages
DC Power (watts)
7
50 Volts
8
Negative 50 Volts
9
Unregulated
10
Negative 15 Volts
Unregulated 15 Volts
11
AC Volts 120V
12
AC Volts 240V
Wiper Alignment
R#
Definition
The engage wiper
0
position (min)
Upper hard stop
1
wiper position (min)
4-52
Typical Value
Actions
~4.79 to 5.0
~1.68 to 1.76
~2.38 to 2.46
~3.17 to 3.24
~11.25 to 11.85
~ 2.38 to 2.47
-13.1 to -12.26
20 to 27.4
47 to 52
-47 to -52
-16.5 to -13.5
MFG Only
90 to 140
180 to 275
Typical
Value
Actions
MFG
Reports the distance from wipe home to the tilt
Only
engage position.
MFG
Reports the distance from wipe to home to the
Only
upper hard stop.