Xerox WorkCentre C2424DX Service Manual page 195

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

X-Axis Drive (Continued)
This test drives the X-Axis motor in each directions until the printhead stalls into the stops, and
then moves the printhead into the clear and performs an on-the-fly reversal. The power profile is
used to confirm operational goals.
R#
Definition
Left Right Traverse
5
Power Ripple (watts)
Turnaround Power
6
Blip Width (watts)
Transfix Drive Slow and Transfix Drive Fast
With the drum turning at a constant velocity, the transfix roller is loaded against the drum, held for
one revolution, then raised. The velocity with which the transfix roller is moved differs for the two
tests.
R#
Definition
Time to first
0
contact (sec)
Loaded
1
average Y-
axis following
error (mpts)
Loaded Y-
2
axis following
error ripple
(mpts)
Time to last
3
contact (sec)
General Troubleshooting
Typical
Value
MFG
Only
4.3 to
10.85
Typical
Value
Fast
Slow
0.22 to
MFG
0.29
Only
2600 to
MFG
3800
Only
150 to
MFG
1100
Only
-0.001 to
MFG
0.8
Only
Actions
Same as R3 except for the other direction of.
motion.
Reports the width of the momentary drop in the
required drive power when the printhead
motion is being reversed. An abnormal value
may indicate an unusual amount of play in the
drive mechanism.
Actions
Reports the time from the load command to
the engine until the drum indicates contact
with the pressure roller.
Reports the average Y-axis following error
during the Roll With Transfix Roller Down
interval.
Reports the difference between the max
and min Y-axis following errors during the
Roll With Transfix Roller Down interval.
Reports the time from the unload command
to the engine until the drum indicates no
further contact.
4-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre c2424

Table of Contents