Xerox WorkCentre C2424DX Service Manual page 201

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

Y-axis Belt Slip
This test does a chase using a special sheet of preprinted media and records the y-axis following
error.
R#
Definition
Initial Peak Y-axis
0
FE (mpts)
Max Following Peak
1
Y-axis FE (mpts)
Average Y-axis FE
2
(mpts)
Y-axis Belt Tension
This test modifies the y-Axis servo loop so that it is unstable and oscillates. The oscillation
frequency is recorded while the drum is advanced for two revolutions. Checks for correct belt
tension and for variations in tension during operation.
R#
Definition
Min Resonant
0
Frequency (hz)
Max Resonant
1
Frequency (hz)
Min Resonant
2
Frequency Revs
(revs)
Min Resonant
3
Frequency Angle
(deg)
General Troubleshooting
Typical
Value
Actions
3500 to
Reports the amplitude of the first Y-axis
6900
following error peak.
3659.3 to
Reports the amplitude of the maximum Y-axis
6500
FE peak after the first.
1500 to
Reports the average of the Y-axis following
3000
error during the roller down portion of the
transfix operation.
Typical
Value
Actions
MFG
Reports the min resonant frequency over the
Only
data set.
MFG
Reports the max resonant frequency over the
Only
data set.
MFG
Reports the number of full Y-axis revs required
Only
to locate the min frequency configuration.
MFG
Reports the amount of additional Y-axis
Only
rotation required to locate the min frequency
configuration.
4-43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre c2424