Xerox WorkCentre C2424DX Service Manual page 204

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

X-Axis Motor
This test turns on the X-axis motor and runs it very slowly for one revolution.
R#
Definition
Motor Voltage A
0
Ripple (volts).
Motor Voltage A
1
Average (volts)
Motor Voltage B
2
Ripple (volts)
Motor Voltage B
3
Average (volts)
Motor Drive Power
4
Ripple (watts)
Motor Drive Power
5
Average (watts)
Process Motor
This test turns on the process motor and runs it very slowly for one revolution.
R#
Definition
Motor fe ripple
0
(ticks)
Motor fe average
1
(ticks)
Motor drive voltage
2
ripple (volts)
Motor drive voltage
3
(volts)
Motor drive power
4
ripple (watts)
Motor drive power
5
average (watts)
4-46
Typical
Value
Actions
MFG
Reports amount of variation of the motor
Only
phase A drive voltage over the recording
interval.
-0.12 to
Reports the motor phase A drive voltage
0.13
average value over the recording interval.
MFG
Reports amount of variation of the motor
Only
phase B drive voltage over the recording
interval.
-0.2 to
Reports the motor phase B drive voltage
0.2
average value over the recording interval.
0.5 to 2.0
Reports amount of variation of the motor drive
power over the recording interval.
9 to 13
Reports the motor drive power average value
of the recording interval.
Typical
Value
Actions
2.8 to 6.0
Reports amount of variation of the motor
following error over the recording interval.
-5 to -2.5
Reports the motor following error average
value of the recording interval.
5 to 11
Reports amount of variation of the motor drive
voltage over the recording interval.
1.3 to 2.3
Reports the motor drive voltage average value
of the recording interval.
1.03 to
Reports amount of variation of the motor drive
3.6
power over the recording interval.
0 to 5
Reports the motor drive power average value
of the recording interval.