Xerox WorkCentre C2424DX Service Manual page 203

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

Stripper Contact (Continued)
This test holds the drum stationary while the stripper solenoid is activated and released. The
drum servo error signal illustrates activation/deactivation timing and how strongly the drum was
contacted by the blade.
R#
Definition
Releasing Amplitude
7
(mpts)
Drum Maintenance Contact
This test uses the drum servo error signal to indicate when the drum is contacted by the roller
blade.
R#
Definition
Initial Contact
0
Position (pm motor
counts)
Check Motors Menu
Y-Axis Motor
This test turns on the Y-axis motor and runs it very slowly for one revolution.
R#
Definition
Motor fe ripple
0
(ticks)
Motor fe average
1
(ticks)
Motor drive voltage
2
ripple (volts)
Motor drive voltage
3
(volts)
Motor drive power
4
ripple (watts).
Motor drive power
5
average (watts)
General Troubleshooting
Typical
Value
Actions
-12.3 to
Reports the magnitude of the reaction of the
5.85
drum to the blade withdrawal (see R3).
Typical
Value
Actions
MFG
Reports the distance the pm motor was moved
Only
(raising the dm unit), before a Y-axis reaction
was detected. Shows that the dm is raising,
provides blade/drum gap information.
Typical
Value
Actions
0.08 to
Reports amount of variation of the motor
0.6
following error over the recording interval.
0.3 to 0.8
Reports the motor following error average
value of the recording interval.
0.34 to
Reports amount of variation of the motor drive
1.3
voltage over the recording interval.
-.75 to
Reports average value of motor drive voltage
-1.5
over the recording interval.
0.25 to
Reports variation of motor drive power over the
1.8
recording interval.
0.5 to 3.0
Reports average value of motor drive power
over the recording interval.
4-45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre c2424

Table of Contents