Testing Motor And Solenoid Resistances - Xerox WorkCentre C2424DX Service Manual

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

Testing Motor and Solenoid Resistances

1.
Turn off the system and disconnect the power cord.
2.
With a DMM set for measuring resistance, test each motor's windings for correct
resistance (disconnected from the system). Rotate the motor's drive shaft slightly
while taking the measurement.
Motor and Solenoid Resistances
Motor or Solenoid
Process motor
Y-axis motor
X-axis motor
Media path motor
Wiper drive clutch
Paper-pick clutch
Deskew clutch
MPT Pick solenoid
General Troubleshooting
Resistance (Approximate)
4.3 ohms +/-15% (Difficult to measure due to variability at
the brush/commutator interface.)
1.4 ohms +/- 15% (Difficult to measure due to variability
at the brush/commutator interface.)
12.5 ohms/phase (red-to-yellow and blue-to-orange)
1.5 +/- 20% ohms/phase
132 ohms +/- 15%
186 ohms +/- 15%
124 ohms +/- 5%
4-75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre c2424

Table of Contents