Xerox WorkCentre C2424DX Service Manual page 166

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

Service Diagnostics Main Menu Definition Table (Continued)
Menu Item
Main Menu --> Scanner Menu
Test Name
Report FW Version
Report Status
Perform Selftest
Test DRAM
Test Homing
Test Axis Unlock
Test Data Capture
Monitor Sensors
4-8
Description
Reports the current firmware version.
Checks then reports the
current status as reported by
the scanner unit firmware.
This test commands the
scanner subsystem to
perform its built-in self test
proceedure, including a
DRAM test. The test will fail
if the scan head is locked.
Tests the scanner
subsystem DRAM.
Runs the scanner axis seek
home procedure. The axis
moves a short distance to
the left, then moves right to
the home sensor.
The axis attempts to move a
short distance to the right.
The test will make strange
noises if the scan head lock
is still engaged.
The scan axis moves to the
right, under the calibration
strip with the light on, then
back to the home position.
This monitors all scanner
unit sensors.
Description
Results
Ready or Not Ready
Lamp:
ON, OFF, Warming Up,
Warmup test not done,
Test fail
Error:
OK, Internal test failure,
Test fail, Data capture test
fail, Seek Home test fail,
Unlocked Check test fail.
OK or Fail.
(This operation may take
several minutes to complete.)
OK or Fail.
(This operation may take
several minutes to complete.)
OK or Fail.
OK = Unlocked
Fail = Locked
OK or Fail.
Cover open or closed.
(The cover must be open
approximately 60 degrees
before the test preports a
change.)
WorkCentre C2424 Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre c2424