Xerox WorkCentre C2424DX Service Manual page 135

Hide thumbs Also See for WorkCentre C2424DX:
Table of Contents

Advertisement

37,027.45:
PEST - X-axis motor disconnect. The X-axis motor is not drawing the
expected power from the supply (both phases).
37,028.46:
PEST - X-axis motor disconnect. The X-axis motor (first phase) is not
drawing the expected power from the supply.
37,029.47:
PEST - X-axis motor short. The X-axis motor is drawing too much power
from the supply (first phase).
37,030.48:
PEST - X-axis motor disconnect. The X-axis motor (second phase) is not
drawing the expected power from the supply.
37,031.40:
PEST - X-axis motor short. The X-axis motor is drawing too much power
from the supply (second phase).
Troubleshooting Procedure
Step
Questions and Actions
Run the X-axis Drive test.
1
1.
Did the test pass?
2.
Check the X- axis motor wiring for damage.
2
1.
37,032.41:
PEST - Y-axis motor disconnect. The Y-axis motor is not drawing the
expected power from the supply.
37,033.42:
PEST - Y-axis motor short. The Y-axis motor is drawing too much power
from the supply.
Troubleshooting Procedure
Step
Questions and Actions
Remove any obstructions interfering with
1
1.
drum rotation.
Inspect the drum and ensure the drum
2.
rotates smoothly, if not replace the drum and
retest.
Did this correct the problem?
3.
Disconnect the Y-axis belt.
2
1.
Does the Y-motor shaft rotate smoothly?
2.
Reconnect the Y-axis belt.
3
1.
Run the Y-axis Motor test.
2.
Did the test pass?
3.
Check the wiring for damage.
4
1.
Error Messages and Codes
Yes
Replace the
Go to Step 2.
electronics
module.
Replace the X-axis motor.
Yes
Complete.
Go to Step 2.
Go to Step 3.
Replace the
Y-axis motor.
Replace the
Go to Step 4.
electronics
module.
Replace the Y-axis motor.
No
No
3-43