Service Diagnostics Main Menu Definition Table (Continued)
Menu Item
Test Name
Test Data Capture
Test Cal Motion
Monitor Sensors
Exercise feed
motion
Exercise Lamp
Reset Doc Handler
Main Menu --> Control Panel Menu
Test Name
Report FW Version
Monitor Buttons
Exercise Display
Exercise LEDs
4-10
Description
Performs the built-in optical
test procedure to determine
if the system can capture
scan dats, the calibration
device, the lamp, optics and
electronics are functional.
Commands the DADF
subsystem to move the
calibration strip into the
scanning window.
Exercises the transport
rollers in the DADF. Monitors
the paper present sensor.
You can manually excercise
the sensor flags and verify
the results.
Cycles the DADF lamp on,
then off. The lamp is then
left ON.
This test power cycles the
IIT unit (MEP, Scanner,
DADF).
Description
Reports the current firmware version.
Reports each button
pressed.
Manually press each button.
Cycles the display to verify
backlight pixels and
operation.
Exercises each LED (Top to
bottom and left to right).
Description
Results
OK or Fail.
OK or Fail.
Paper or no paper.
OK or Fail.
There should not be media
present to perform this test.
OK or Fail.
The lamp state must be
manually observed.
Ready or Not Ready
Results
Pressed and released.
All dark = No Backlight
All light = Backlight ON
ON, Blink, or OFF.