POST Error Reporting Blink Pattern Definition Table (Continued)
Control
Panel
PS, PE and
Error
Control
Code
Panel LEDs
15.07
Flutter and
then 15 blinks
15.08
Flutter and
then 15 blinks
15.09
Flutter and
then 15 blinks
15.10
Flutterand
then 15 blinks
15.11
Flutter and
then 15 blinks
16.01
Flutter only
16.02
Flutter only
16.03
Flutter only
16.04
Flutter only
17.01
Flutter and
then 17 blinks
18.01
Flutter and
then 18 blinks
18.02
Flutter and
then 18 blinks
18.03
Flutter and
then 18 blinks
18.04
Flutter only
19.01
Flutter and
then 19 blinks

PEST Error Reporting

PEST tests occur after POST tests have been run and PostScript has been initialized.
PEST checks the connections and operation of various system components.
Error codes for PEST tests are displayed on the control panel and are all in the
37,XXX.xx series. For troubleshooting PEST error codes, see "37,0XX.xx Errors -
PEST Faults" on page 3-37.
Error Messages and Codes
POST
Error
Type
Description
CPU interrupt error, spurious assertion.
Hard
CPU interrupt error, no assertion.
Hard
CPU interrupt error, spurious assertion.
Hard
CPU interrupt error, no assertion.
Hard
CPU interrupt error, IRQ spurious assertion.
Hard
Real time clock read failure.
Soft
Real-time clock write failure.
Soft
Real-time clock re-read failure.
Soft
Real-time clock does not tick.
Soft
Memory test, less than 128 MB of RAM
Hard
detected. This is the minimum RAM required.
Add more RAM. Reseat the RAM SODIMM(s),
then replace the RAM SODIMM(s).
IPCB ID read failure.
Hard
IPCB ID mismatch.
Hard
IPCB PCI configuration failure.
Hard
IPCB version mismatch.
Soft
Check and reseat cables. Replace hard drive, if
Hard
necessary.
3-7