Y-axis Encoder (Continued)
Uses the sine and cosine sum data to determine the characteristics of the encoder disk and
encoder sensors.
R#
Definition
Amplitude Ripple
7
(Sun Sum units)
Max Position Ripple
8
(mpts)
Y-axis Geometry
Rotates the drum at a constant velocity and samples the Y-axis position. Uses the data to
determine Y-axis motor and drum vibration and the most significant other vibrational frequencies.
R#
Definition
Drum Normalized
0
FFT Power (none)
Drum Frequency
1
(hz)
Motor FFT Power
2
Ratio (none)
Motor Frequency
3
(hz)
FFT Power Ratio 1
4
(none)
Frequency 1
5
Frequency (hz)
FFT Power Ratio 2
6
(none)
General Troubleshooting
Typical
Value
Actions
MFG
Reports the ripple in the Sin Sum amplitude
Only
values. Excludes the neighborhood of the
Home notch (a distance of +/- 50 samples from
the Home notch min location.
MFG
Reports the max variation in the reported delta
Only
position between samples over the revolution.
Typical
Value
Actions
MFG
Reports the normalized FFT power amplitude
Only
of the drum frequency. The normalized value is
generated by dividing the drum FFT power by
1.0xE13.
MFG
Reports the current drum frequency.
Only
MFG
Reports the ration of the FFT power amplitude
Only
of the motor frequency to the FFT power
amplitude of the drum frequency.
MFG
Reports the current motor frequency.
Only
MFG
Reports the ratio of the FFT power amplitude
Only
of the most powerful FFT frequency (not
including the drum or motor), to the FFT power
amplitude of the drum frequency.
MFG
Reports the frequency of the most powerful
Only
FFT frequency (not including the drum or
motor).
MFG
Reports the ratio of the FFT power amplitude
Only
of the second most powerful FFT frequency
(not including the drum or motor), to the FFT
power amplitude of the drum frequency.
4-41