Media Path Motor
This test turns on the media path motor and runs it very slowly for one revolution.
R#
Definition
Motor fe ripple
0
(ticks)
Motor fe average
1
(ticks)
Motor drive voltage
2
ripple (volts)
Motor drive voltage
3
(volts)
Motor drive power
4
ripple (watts)
Motor drive power
5
average (watts)
Tray 2, Tray 3, Tray 4, Lift Motor
This test turns on the specified motor and runs it at constant velocity for approximately 20
revolutions while recording drive data. The test is the same for each motor. Requesting a test for
a 525-sheet feeder that is not installed will generate an "Option Not Detected" message.
R#
Definition
Motor Peak Power
0
(watts)
Motor Average
1
Power (watts)
Brake Average
2
Power (watts)
General Troubleshooting
Typical
Value
Actions
.4 to 1.3
Reports amount of variation of the motor
following error over the recording interval.
0.8 to 2.0
Reports the motor following error average
value of the recording interval.
4 to 10
Reports amount of variation of the motor drive
voltage over the recording interval.
-5 to 0
Reports the motor drive voltage average value
of the recording interval.
0.8 to 6
Reports amount of variation of the motor drive
power over the recording interval.
1.9 to 7
Reports the motor drive power average value
of the recording interval.
Typical
Value
Actions
MFG
Reports max amount of motor power over the
Only
run interval.
MFG
Reports the average motor drive power over
Only
the last half of the run interval.
MFG
Reports the average motor brake power over
Only
the stop with brake interval.