INITiate:CONTinuous:TRANsient 0|OFF|1|ON, (@<chanlist>)
INITiate:CONTinuous:TRANsient? (@<chanlist>)
Continuously initiates the transient trigger system. This allows multiple triggers to generate multiple
output transients.
Parameter
0|OFF|1|ON , *RST ON
Continually initiates the trigger system: INIT:CONT:TRAN ON, (@1)
With continuous triggering disabled, the trigger system must be initiated for each trigger using the
l
INITiate:TRANsient command.
ABORt:TRANsient
does not abort continuous triggers if INITiate:CONTinuous:TRANsient ON has
l
been programmed. In this case, the trigger system will automatically re-initiate.