Mounting; Mounting Of Sensor - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
3

Mounting

Pos: 18 /Sc hweis snaht/ Senso ren/Mon tage/SN-Sen soren/Ru ndkörper/ Senso rmonta ge @ 0\mod _112 721 066 5578 _50 1.docx @ 601 @ 2 @ 1
3.1

Mounting of sensor

Basically, the sensor can be mounted in any orientation. However, an overhead mounting (sensor
face looking down) is favourable, since the sensor will be less contaminated.
The sensor must be installed so that the weld seam runs right-angled to the direction of motion. It
must be assured, that all rollers of the sensor are contacting the tube and turn when the tube
rotates. The provided rubber mounts are intended for the installation of the sensor. Thus the sensor
adapts to the tube.
1
Fig. 6: Mounting of sensor
The sensor mounting bracket substantially influences the correct function. If the sensor is mounted
in a rigid mounting bracket, it can happen that the sensor contacts the tube only at one side. This
will lead to unwanted one-sided pressure distribution on the sensor. In addition, such uneven
contact with the tube provokes faulty measurements.
Thus the sensor should be mounted using the provided rubber buffers as well as an air cylinder
(see next picture). The sensor does not need to be pressed onto the tube, the own weight of the
sensor is sufficient.
Depending on mechanical arrangement, it might be necessary to equip the sensor bracket with
springs.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
2
Manual
Description
For the explanation of
principle the sensor is shown
here under the tube. In the
practical case, the sensor
should be preferably set
above the tube.
1: Weld seam
2: NS-Sensor
Mounting
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents