Technical data
9.27

Sensor cable CECM18S-G

Usage: Connecting the combo sensors and the eddy current sensors to the control unit.
On using eddy current probes, the sensor connection box SCB-EC-S must be used additionally.
The cable has a cable socket at the sensor side, and open end wires with wire-end ferrules at the
control unit side. Standard length is 5 meters, other lengths must be specified.
Cable socket at sensor side: Coninvers M18, Roland 2276010
Fig. 66: CECM18S-G
Cable diameter:
Structure:
Bending radius:
Pos: 105 /Schweis snah t/Kabel/SM1 8CECM18 S-G G @ 1\mod _12 1811 711 473 4_50 1.docx @ 725 3 @ 2 @ 1
9.28

Sensor cable SM18CECM18S-GG

Usage: Connecting the Eddy current sensors as well as the combosensors and the encircling
coils to the sensor switch box.
For using Eddy current probes the Sensor Connection Box SCB-EC-S must be used in addition.
The cable has a cable socket at the sensor side and a cable plug at the switch box side.
Standard cable length is 5 meters, other lengths upon request.
1
5
2
4
3
Cable plug at Switch box side
Roland 2277010, M18,
supplier: Coninvers
Fig. 67: Cable SM18CECM18S-GG
Cable diameter:
Structure:
Bending radius:
Pos: 106 /Schweis snah t/Sen sore n/Zu behör/ Swit ch Box/SSB- SN D40 @ 0\mod_1 147 0784 030 46_ 501.do cx @ 20 77 @ 2333 @ 1
120
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
9.5 mm
2
2 × 2 × 0.25 mm
, CY – PIDY(TP)
57 mm, laid fixed
150 mm, laid flexible
Cable socket at Sensor side
9.5 mm
2
2 × 2 × 0.25 mm
, CY – PIDY(TP)
57 mm, laid fixed
150 mm, laid flexible
Manual
1: green
2: yellow
5
1
3: Inner cable
4
2
3
4: white
5: brown
External cable shielding connected to
Roland 2276010, M18,
supplier: Coninvers
B0059001 / Rev. 2.3
1: green
Transmitter / a
2: yellow
Transmitter / b
3: Inner
Ground
stranded
cable
shields
4: white
Meas. signal 1
5: brown
Meas. signal 2
External cable shield
to socket enclosure
Sender / a
Sender / b
Ground
shieldings
Meas. signal 1
Meas. signal 2
enclosure