Technical records
11.2.4.3 Retro-fitting the cable driver module
Fig. 88: Retro-fitting the cable driver module
Loosen all cable plugs and the 4 fixing screws.
Every screw connection consists of an M3 screw, a toothed washer and a flat washer.
Do not lose any parts, danger of short-circuit.
Note: Older units are equipped with a flat plug at the lower right screw joint.
Do not forget this when mounting the driver module.
Replace every screw by one of the provided spacer bolt.
Plug-on the cable driver module.
Take care that every connector at the module gets into the corresponding contact on the
eddy current module.
Fasten the module with the remaining screws.
For older units: re-attach the flat plug for the shielding connection.
Re-plug all cables onto the cable driver module.