7.7.1
Modifying of system parameters
If system parameters need to be changed, proceed as follows:
Press the <System> key when being in the measurement mode.
Press the <modify setup> key.
If a password is existing, the password inquiry appears.
Then type-in the valid password and confirm with <Enter>. Only then access to the system
settings is permitted.
If no password is existing, the password inquiry will not be called up.
With the <arrow> keys access the entry to be changed from the parameter list to the right
and change with the <+> / <-> keys.
With the <save> key store the entry or dismiss with <cancel>.
If a restart is required, the system will perform it automatically ( systems following serial
number 400059 / SW version 1.16 ).
It is recommended to note down all changes, in order to enable easy return to the previous settings
in case of doubt.
Pos: 58 /Sc hweis snaht/ Geräte/ SN D40/8 Bet rieb/Rundkö rpe r/Erstelle n und Bea rbeiten Me ssp rog ramme @ 0\mod _11 659 9383 345 3_5 01.docx @ 240 7 @ 2 @ 1
7.8

Creating and editing of measuring programs

In the measuring programs the parameters for detecting and positioning the weld seam are stored.
We recommend to create product specific / tool specific measuring programs, in order to consider
all variables (material, wall thickness, width of weld seam, etc.) which are important for optimal
detection.
For creating / editing a measuring program first insert a sample tube into the turn drive and with the
<Program> key change over to the "Setup – Program selection" mode. There select an empty
program place or the program to be edited.
1.
With the key <Edit program> change over to the "Setup – Test operation".
2.
Enter parameter "Description" and "Diameter" (only for initial editing).
3.
Enter parameter "Rotation" or "Speed" (coarse value).
4.
Enter parameter "Sensor signal":
When using the sensors NS9S, NS12S or the NSL sensors, select "Leakage flux";
when using the sensors NS9-EC..., select "Leakage flux" or "Eddy current";
when using the sensors EC..., select "Eddy current".
5.
Press the <Speed measurement> key:
When measuring the speed, the parameter
„Rotation" or "Speed" should have a plausible
value.
In the visualisation of the signal there should
be 2 weld seam signals visible:
6.
Press the <Start test job> key.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Note:
Creating of new programs can be simplified by copying of existing programs and
modifying them, if they are intended for similar tubes.
Manual
Fig. 43: Speed measurement