Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

Technical records
Pos: 125 /Schweis snah t/Gerä te/SN D40/1 1 Tech nis che Un terla gen/Se rvice/Da tens iche run g über Netzwe rk @ 0\mod_ 114 364 3120 734 _50 1.docx @ 2005 @ 3 @ 1
11.2.3 Data backup via network
Data backup can be done via Ethernet or by USB interface (for newer hardware).
Data backup via Ethernet is performed within a Telnet session.
Note:
For the term "Host-PC-name" used in this section, the respective Windows name of the
PC must be inserted. The PC name can be found via
"my computer" -> "properties" -> "computer name".
1.
Create a new folder, e.g. „SND40-backup" on the Host PC, which permits full access with the
access name „netdcu".
2.
Start a Telnet session on the Host PC (towards SND40).
Therefore:
Open the command prompt (Start > Run) and enter "CMD" and confirm with <ENTER>.
Enter "telnet 192.168.100.107" and confirm with <ENTER>.
3.
Copy data:
Generally:
Copy files from the SND40 to the Host PC:
Enter "cd \ffsdisk" and confirm with <ENTER>.
Enter "copy *.cfg \\Host-PC-name\netdcu\" and confirm with <ENTER>
(this will copy the program files and the system settings).
Enter "copy statistics.log \\Host-PC-name\netdcu\" and confirm with
<ENTER> (this will copy the Log files).
Now all files should be reported as copied.
For verification enter "dir" and confirm with <ENTER>. All files in the directory will be
shown. Verify if all files have been copied.
Copying files from the HOST PC to the SND40:
Attention!
Enter "cd \ffsdisk" and confirm with <ENTER>.
Enter "copy \\"Host-PC-name"\netdcu\*.*" and confirm with <ENTER>.
Now all files should be reported as copied.
For verification enter "dir" and confirm with <ENTER>. All files in the directory will be
shown. Verify if all files have been copied.
Data backup via USB stick is performed by the enclosed software "SND40Store". For details read
"SND40 Store" in chapter "Maintenance and repair". When using newer hardware, a backup via
USB stick should be preferred.
Pos: 126 /Schweis snah t/Gerä te/SN D40/1 1 Tech nis che Un terla gen/Se rvice/Kompo nenten taus ch und Nach rüs tung @ 0\mod_ 114 7437 807 187 _501. docx @ 2091 @ 344 4 @ 1
158
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Always copy data from / to folder "ffsdisk" on the SND40.
The files on the SND40 will be overwritten without further notice !!!
Manual