Maintenance
Please type „ > reg save" und confirm with „Enter" button.
Re-start the system by recovering the supply voltage.
Pos: 119 /Schweis snah t/Gerä te/SN D40/1 0 Wa rtun g/Kalibrieren des Tou chs creen s @ 2\mod _13 2265 573 501 1_50 1.docx @ 102 99 @ 2 @ 1
10.7

Calibrating the touchscreen

Method 1: Calibration via Remote connection
Note:
Establishing a Remote connection is described in this manual, section
"Service function Remote Desktop".
Establishing a Telnet connection is also described in this manual, section
"Data backup via network", item 1 + 2.
At the PC establish Remote connection with Remote Desktop, so that the SND40 can be
remote operated.
Terminate SND40 program (ESC key).
Click in the left bottom corner to make the taskbar visible.
138
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Manual
B0059001 / Rev. 2.3