Technical data
9.21
Eddy current probe EC30x25IT10-100-S
Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Arrangement:
Width of track:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Sensor Connection Box:
Fig. 59: EC30x25IT10-100-S
Pos: 98 /Sc hweis snaht/ Senso ren/EC (Wi rbel st romson den)/EC12x4 0IRT1 0-100- S @ 0\mod _11 295 5734 496 8_5 01.docx @ 841 @ 2 @ 1
114
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material
Flat material
unlimited
Depending on material
Eddy current
axial
16 mm
20 mm
10 - 40 °C (50 – 104°F) (operation)
IP65
0.3 kg (0.66 lbs)
Stainless steel
SM18CECM18S-GG
SCB-EC-S
Manual
Description
1:
View – active area
2:
Direction of material flow
3:
Cable plug
order no.: 2277704
1:
View – active area
All dimensions in mm
B0059001 / Rev. 2.3