4. Mounting

The mounting of the Double Sheet Detector R1000 UDK20 determines the measurement accuracy and the
reliability of operation. The system was designed for operating in rough industrial environments. However,
the following mounting instructions should be observed in order to minimize mechanical, thermal and
electromagnetic influences on the operation.

4.1 General mounting instructions

The enclosure for wall mounting meets IP 65 and is designed for mounting the enclosure close to the sensor
location. So, shorter shorter sensor cables can be used, which causes lower exposure to electromagnetic
noise. This will lead to better measurement results.
The control unit should be installed in locations where no vibration exists and no additional heat is transferred
into the system (even better reduce the heat in the control unit). In addition the control unit should be installed
in such a fashion that it can be easily opened for service purposes. During operation, control unit and sensors
should be under visual control of the operating persons.
Attention: Exposing the control unit to strong vibrations and additional heat can damage the unit.
For mounting the unit into switch panels or operator consoles, the front panel version should be used.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33