Roland R4000 Manual page 149

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
Standard wiring of interface
Operational condition: Setup - Edit
Pre-condition:
1.
The unit must be in "Setup - Edit" condition.
2.
System parameter "Test job control mode: PLC".
3.
Test job or speed measurement (is started by key operation and automatically terminated).
By pressing the button the SND40 outputs the signals to the PLC. The staus message "Waiting for PLC start" is
generated by the SND40. The PLC prepares a tube for detection and gives the signal "start test job" to the SND40.
Parallel Data Inputs
Parallel Data Outputs
OUT0 / Start Test job active
OUT2 / Ready for measuring
OUT6 / Reduced detecting capability
t1:
< 100 ms
t2:
Time which the PLC needs to prepare a tube for parameter programming (Putting-on the tube).
t3:
< 30 ms
t4:
Duration of test procedure / locating of rotation rate is according to tube diameter and tube rotation rate.
t5:
≥ 0 ms
t6:
At the end of the test procedure / locating of rotation rate the Start signal must be cancelled.
t7:
> 30 ms
The duration of parameter optimization (test job / locating of rotation rate) depends on tube diameter, tube rotation rate and
the time required for entering the parameters.
Test job:
Speed measurement
1)
Not mentioned inputs / outputs of the interface are not required for parameter programming.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Key / Start test job
1)
IN0 / Start test job
1)
OUT3 / Setup active
OUT4 / Slippage
OUT5 / General fault
OUT7 / Motor
Transient time + 3 to 4 tube turns
approx. 60 s transient time + 5 tube turns
Manual
t3
t1
t2
t4
Technical records
t7
t5 t6
149