Operation
7.2
Measuring operation
After powering up, the system automatically switches over to the measuring operation.
1
2
Fig. 37: Measuring operation
Pos: 51 /Sc hweis snaht/ Geräte/ SN D40/8 Bet rieb/Rundkö rpe r/Ein ric hten P rog rammauswa hl @ 0\mod _11 689 6159 181 2_5 01.docx @ 246 3 @ 2 @ 1
70
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
4
Changes over to the program
selection.
Changes over to the system
parameter selection.
Changes over to the statistics
function.
Note:
The result of the weld seam detection is stated in dB (signal amplitude within the
weld seam vs. signal amplitude outside the weld seam).
Note:
Starting with firmware version V23 following behaviour has been observed: At a
data amount of 5000 values per rotation the signal transmission is suspended. In
the display only a horizontal line appears. To avoid this, the parameter "sample
rate" can be set to a lower value, for example to 30.
Manual
Screen area
1:
2:
3
3:
4:
Prints out the signal visualization and a
list of the program parameters.
No key function in this mode.
Selects the parameters from the list.
No key function in this mode.
B0059001 / Rev. 2.3
Visualization of the sensor
signal (original signal und
digitally filtered signal) and
a control signal.
Indication of
weld seam width
according to entry
"weld seam width [%]".
List of measuring results.
List of parameters of the
activated measuring
program.
Indication of program status
and operation condition,
see chapter "Maintenance
and repair".