Communication with the PLC
5.2.7
CSP file for CC-Link
To simplify network configuration, CC-Link devices may be associated with CC-Link System
Profile, also known as a CSP-file. This file contains a description of the device and can be used by
some CC-Link system utilities to simplify the configuration process. The CSP file is supplied on a
CD or can be downloaded from the ROLAND ELECTRONIC homepage.
One „occupied Station" is used. The station type is "Remote Device".
2 Byte are Bit Data Area, 2 Byte are System Area and 4 Byte Word Data Area. The meanings of
the Bit are explained in chapter 5.1.
Link Input RWrn(Roland R1000 => PLC)
Bit data area: not used
System area: Bit 3 = Remote Ready *1)
*1) Remote Ready: after Roland SND40 is ready for Data exchange the signal Remote READY is set. If Remote READY is
off the Data in the user area are not valid.
Word data area 2 Word
Word number
RWr0
RWr1
Link Output RWwn (PLC => Roland R1000)
Bit Data area: not used
System area: not used
Word data area 2 Word
Word number
RWw0
RWw1
For diagnostics, the LEDs at the fieldbus module may help.
Pos: 41 /Sc hweis snaht/ Geräte/ SN D40/6 Kommu nikat ion mit der SPS/Ü berwach ung de r Steue r-Eingä nge/Ausgän ge @ 0\mod_ 114 888 8551 827 _50 1.docx @ 2173 @ 2 @ 1
60
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Roland Byte
RWr0.0-7= BIN1
RWr0.8-F= BIN0
RWr1.0-7= BIN3
RWr1.8-F= BIN2
Roland Byte
RWw100.0-7= BOUT1
RWw100.8-F= BOUT0
RWw101.0-7= BOUT3
RWw101.8-F= BOUT2
Status Indicators
Nr.
LED
State
LED 1 RUN
Green On
Green Off
LED 2 ERRL
Red On
Red Off
LED 3 RDLED
Green On
Green Off
LED 4 SDLED
Green On
Green Off
Manual
Ready / Not used
General Control
Fault identification
Active Program number
Function
Not used
General Control
Not used
Program number
Description
Normal operation
Network non-participating or timeout status
No power on the module
CRC Error detected
Illegal station number or illegal baud rate detected
Normal Operation
No power on the module
Data being received
No data reception
No power on the module
Data being transferred
No data transmission
No power on the module
B0059001 / Rev. 2.3