Eddy Current Sensor Ec9-8X60Nt10-100-S; Eddy Current Sensor Ec9-8X60Nf10-100-S - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
Pos: 83 /Sc hweis snaht/ Senso ren/N S9/EC9- 8x60NT 10-10 0-S Te chni sche Daten @ 0\mod_1 121 265 9291 09_ 501.do cx @ 5 67 @ 2 @ 1
9.10

Eddy current sensor EC9-8x60NT10-100-S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring
patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole
boots and tube surface
Air gap between sensor
element and tube surface
Pos: 84 /Sc hweis snaht/ Senso ren/N S9/EC9- 8x60NF1 0-100- S Tech nis che Da ten @ 0\mod _11 295 5339 943 7_5 01.docx @ 82 3 @ 2 @ 1
9.11

Eddy current sensor EC9-8x60NF10-100-S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material (non-ferrous tubes)
10 - 250 mm
Depending on material
Eddy current
4 mm
10 - 40 °C (50 – 104 °F) (operation)
IP53
5.6 kg (12.4 lbs)
Aluminium, nickel plated
CECM18S-G
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Round material (non-ferrous tubes)
10 - 250 mm
Depending on material
Eddy current (high resolution)
2 mm
10 - 40 °C (50 – 104 °F) (operation)
IP53
5.6 kg (12.4 lbs.)
Aluminum, nickel plated
CECM18S-G
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Manual
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
Technical data
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents