Combination sensor NS9-EC8x60NF10-100-S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Pos: 79 /Sc hweis snaht/ Senso ren/N S9/N S9- GMR-S Tech nis che Da ten @ 1\mod _12 372 9903 646 8_5 01.docx @ 82 88 @ 2 @ 1
9.7

Leak flux sensor NS9-GMR-S

Special feature: GMR sensor element, high magnetic resolution, for precision steel tubes.
Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole
boots and tube surface
Air gap between sensor
element and tube surface
Pos: 80 /Sc hweis snaht/ Senso ren/N S9/N S9 Te chn ische Zei chnu ng @ 0\mo d_11 212 637 4440 6_5 01.do cx @ 57 3 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material (ferrous / non-ferrous tubes)
10 - 250 mm
Up to 3 mm / depending on material
Magnetical leakage flux
Eddy current (high resolution, only for non-ferrous material),
relative magnetic Flux = 0%
2 mm
10 - 40 °C (50 – 104 °F) (operation)
IP53
6.6 kg (14.5 lbs.)
Aluminum, nickel plated
KNS9S (leak flux)
CECM18S-G (eddy current)
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Round material (ferrous tubes)
10 - 250 mm
Up to 3 mm
Magnetical leak flux, with GMR element, high resolution
10 - 40 °C (50 - 104 °F) (operation)
IP53
6.6 kg (14.6 lbs.)
Aluminum, nickel plated
KNS9S
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Manual
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
The air gaps must be within the permissible range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
Technical data