Leak Flux Sensor Ns9S; Combination Sensor Ns9-Ec8X60Nt10-100-S - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

Technical data
9.4

Leak flux sensor NS9S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Pos: 77 /Sc hweis snaht/ Senso ren/N S9/N S9-EC8x 60NT 10-10 0-S Tec hni sche Daten @ 0\mod_1 121 2659 056 87_ 501.do cx @ 56 8 @ 2 @ 1
9.5

Combination sensor NS9-EC8x60NT10-100-S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Pos: 78 /Sc hweis snaht/ Senso ren/N S9/N S9-EC8x 60NF1 0-100- S Tech nis che Da ten @ 0\mod _11 295 5426 234 3_50 1.docx @ 826 @ 2 @ 1
94
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material (ferrous tubes)
10 – 250 mm
Up to 3 mm
Magnetical leak flux
10 - 40 °C (50 – 104°F) (operation)
IP53
6.6 kg (14.6 lbs.)
Aluminum, nickel plated
KNS9S
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Round material (ferrous / non-ferrous tubes)
10 - 250 mm
Up to 3 mm / depending on material
Magnetical leakage flux / eddy current
4 mm
10 - 40 °C (50 - 104 °F) (operation)
IP53
6.6 kg (14.5 lbs.)
Aluminum, nickel plated
KNS9S (leak flux)
CECM18S-G (eddy current)
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Manual
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").