Roland R4000 Manual page 109

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
9.18.2 Power supply NT-NS-S
If an increased magnetization power is required at the NS12... sensor, the use of the auxiliary
power supply NT-NS-S is advisable.
The power supply takes over the supply of the NS12 sensor with electrical energy, it will be
controlled by the SND40 system.
Supply voltage:
Output:
Fuse protection:
Startup current:
Triggering:
Ambient temperature:
Connections:
Enclosure:
Class of protection:
Dimensions:
Fig. 54: Dimensions of enclosure and mounting holes
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
90-260V AC 50-60Hz
60-90 VDC, 240 W (set to 75 V)
3.15 A medium-blow, 5×20 mm, in connecting terminal for mains voltage
14 A
Opto coupler input for enabling the output voltage
Relay input for the selection of magnetizing current (valid from serial number C1211)
0...40°C (during operation)
Harting quick connectors
Wall-mount enclosure, Aluminum
IP65
approx. 330×180×110mm (without sockets)
approx. 410×180×110mm (with sockets)
Manual
Technical data
109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents