Roland R4000 Manual page 52

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

Communication with the PLC
Outputs (sourcing outputs)
Terminal parallel
OUT 0
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
The output OUT4 "Weld seam detected (permanent) is only activated in the system configuration at
acknowledge mode.
Terminal parallel
-
-
Terminal parallel
-
-
-
-
-
-
-
-
Terminal parallel
-
52
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Byte.Bit Fieldbus
Name
BOUT0.0
Measurement start active /
Test job start active
BOUT0.1
Program selection active
BOUT0.2
Ready for measuring / (M1)
BOUT0.3
Set up active / (M2)
BOUT0.4
Slippage/weld seam detected
(duration) / (M4)
BOUT0.5
General fault / (M8)
BOUT0.6
Reduced detection capability / (M16)
BOUT0.7
Motor / Weld seam detected (pulse)
Byte.Bit Fieldbus
Name
BOUT1.0
Ready
BOUT1.1-1.7
Not used
Byte.Bit Fieldbus
Name
BOUT2.0
M1
BOUT2.1
M2
BOUT2.2
M4
BOUT2.2
M8
BOUT2.4
M16
BOUT2.5
M32
BOUT2.6
M64
BOUT2.7
M128
Byte.Bit Fieldbus
Name
BOUT3.0-3.7
Fault identification
Note:
For CC-Link assignment see also chapter 4.9.3 "CC-Link Connection".
Manual
Comment
-
-
(...) possible only via parallel interface
Active by program selection
If the program selection is not set, the
function mentioned (without brackets)
can be activated
-
Comment
-
-
Comment
Number of the active program. If no
program is active, number 0 will be
issued.
Comment
See fault reporting table (8-bit)
B0059001 / Rev. 2.3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents