Combination Sensor Ns9-Ec5X30Nt10-100-S - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
9.8

Combination sensor NS9-EC5x30NT10-100-S

Special feature:
Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole
boots and tube surface
Air gap between sensor
element and tube surface
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
extra narrow measuring patch, for tubes > 6mm Ø.
Round material (ferrous / non-ferrous tubes)
6.5 - 10 mm
Up to 3 mm / depending on material
Magnetical leakage flux
Eddy current (high resolution, only for non-ferrous material),
relative magnetic Flux = 0%
2 mm
10 - 40 °C (50 – 104 °F) (operation)
IP53
6.6 kg (14.5 lbs.)
Aluminum, nickel plated
KNS9S (leak flux)
CECM18S-G (eddy current)
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Manual
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
Technical data
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents