Leakage flux sensor NS12S

Technical data
Application:
Diameter of tubes:
Wall thickness:
Measuring principle:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Pos: 86 /Sc hweis snaht/ Senso ren/N S1 2/NS12-EC8x8 0NF10-1 00-S Te chn isc he Daten @ 0\mod_ 112 8418 556 515_ 501. docx @ 6 83 @ 2 @ 1
9.13

Combination sensor NS12-EC8x80NF10-100-S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Pos: 87 /Sc hweis snaht/ Senso ren/N S1 2/NS12-EC8x8 0NT1 0-100- S Tech nis che Date n @ 0\mod _11 9559 100 140 _501. docx @ 8 47 @ 2 @ 1
102
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material (ferrous tubes)
12 - 250 mm
Up to 4 mm
Magnetical leakage flux
10 - 40°C (50 – 104°F) (operation)
IP53
11 kg (24.3 lbs)
Aluminum, nickel plated
KNS9S
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Round material (ferrous / non-ferrous tubes)
12 - 250 mm
Up to 4 mm / depending on material
Magnetical leakage flux / eddy current
(high resolution, only for non-ferrous material),
relative magnetic flux = 0%
2 mm
10 - 40°C (50 – 104°F) (operation)
IP53
11 kg (24.3 lbs.)
Aluminum, nickel plated
KNS9S (leak flux)
CECM18S-G (eddy current)
0.2 ... 0.25 mm in new
condition
0.1 ... 0.35 mm is
permissible range
0.6 ... 0.65 mm in new
condition
0.3 ... 0.75 mm is
permissible range
Manual
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
The air gaps must be within the permissible range.
If the value gets – due to wearing - outside the permissible
range, the sensor needs to be repaired (see also chapter 10
"Maintenance").